Brand Name : Xi'an Shendian
Model Number : TJZB-35
Certification : IEC 60099-4/ GB 11032
Place of Origin : China
MOQ : 1 pc.
Price : To be determined by type and quantity.
Payment Terms : T/T; L/C.
Supply Ability : 1000 pc/year.
Delivery Time : Ex-work 30 days~60 days depends on quantity.
Packaging Details : Seaworthy package/ Customer specified.
Nominal system voltage : 35kV~110kV/ Customer specified
Advantage : Entirety assembly and transportation
Usage : Transformer neutral point protection
Incoming/ Outcoming : Top In Bottom Our/ Side In Side Out/ Bottom In Bottom Out
Certfication : IEC 60099-4/ GB 11032
System Fault Current : 50A~ 5000A
110kV Neutral Grounding Protection Device for Transformer
Product introduction:
This kind of transformer neutral protection device adopts modular construction.
It has been running well in high altitude area over decades year.
| Item | Description | Offered | ||
| 1 | Type | TJZB-110 | ||
| 2 | TR rated voltage | kV | 110 | |
| 3 | Power frequency voltage | kV | 95 | |
| 4 | Lightning impulse voltage withstand | kV | 250 | |
| 5 | Metal-oxide surge arrester | Type | Y(H)1.5W-72/186 | |
| Rated voltage | kV | 72 | ||
| Residual voltage at lightning impulse | kV | ≯186 | ||
| Residual voltage at switching impulse | kV | ≯174 | ||
| Reference voltage at D.C. 1mA | kV | ≮103 | ||
| Leakage current at 0.75U1mA | μA | ≯50 | ||
| 6 | Disconnect switch | Rated voltage | kV | 72.5 |
| Rated current | A | 630 | ||
| Operation mechanism | Motor/ Manual | |||
| Rated short-time current withstand | kA | 31.5 | ||
| Rated peak current withstand | kV | 80 | ||
| 7 | Current transformer | Rated voltage | kV | 10 |
| Rated insulation level | 42/75 | |||
| Rated dynamic current | kA | 110 | ||
| 8 | Discharge gap | Gap type | Ball/ Rod | |
| Power frequecny discharge voltage | kV | 83±10% | ||
| Impulse discharge voltage | kV | ≯215 | ||
| Gap distance | mm | 60~100 adjustable | ||
| 9 | Monitor | Type | JCQ-CⅠ | |
| Current measurement range | mA | 0~5 | ||
| Operation current range | A | 50~20000 | ||

|
110kV Lightning Neutral Grounding Resistor For Transformer Images |
330kV Anti Aging Lightning Neutral Grounding Equipment For Transformer
220kV Lightning Neutral Grounding Resistor For Transformer
110kV Neutral Grounding Equipment with Surge Arrester Plus Switch and CT
Metal Neutral Grounding Resistor Heat Resistant Transformer 20kV 5kA
6.3kV Neutral Grounding Resistor With Good Oxidation Resistance
35kV Neutral Grounding Resistor High Temperature Withstand
10kV Neutral Grounding Resistor For Transformer